Two Coating Routes, Two Different Zinc Structures
Hot-dip galvanized and electro-galvanized coil both protect carbon steel with zinc, but the deposition method decides the coating structure, the attainable coating weight and, in the end, the service life of the finished part. In a continuous hot-dip line the strip travels through a molten zinc bath at roughly 450 °C, so the coating alloys into the steel surface and builds a hard zinc-iron intermetallic layer beneath a pure zinc outer layer. Coating weight is trimmed by gas wiping as the strip leaves the pot. Electro-galvanizing runs at ambient temperature and deposits zinc electrolytically from a sulfate or chloride electrolyte, producing a thin layer that sits on the surface rather than alloying into it.
That structural difference is why the two products are rarely interchangeable. Hot-dip coil is supplied in commercial, drawing and structural qualities with normal spangle, minimized spangle or skin-passed surfaces. Electro-galvanized coil is specified when the surface must stay smooth and paint-ready, and when the part is formed first and used indoors.
Coating Weight and Thickness in Practical Terms
Coating mass is the fastest way to separate the families. Electro-galvanized coatings normally sit between 5 and 30 g/m², while hot-dip coatings start near 30 g/m² and extend past 600 g/m². Zinc has a density of 7.14 g/cm³, so coating mass converts directly into thickness. A Z275 hot-dip coating carries 275 g/m² over both surfaces, equal to about 38.5 µm combined or close to 19 µm per side. A 20 g/m² electro-galvanized coating works out to only about 2.8 µm combined.
| Coating route | Typical coating mass | Combined thickness | Designations in common use |
|---|---|---|---|
| Electro-galvanized | 5-30 g/m² | 0.7-4.2 µm | ASTM A879, JIS G3313 SECC |
| Hot-dip, light | 30-120 g/m² | 4.2-16.8 µm | EN 10346 Z100, JIS G3302 Z12 |
| Hot-dip, standard | 180-275 g/m² | 25-38.5 µm | EN 10346 Z275, ASTM A653 G90 |
| Hot-dip, heavy | 350-600 g/m² | 49-84 µm | EN 10346 Z350 to Z600, ASTM A653 G185 |
ASTM A653 expresses coating as ounces per square foot, so G90 means 0.90 oz/ft² total on both sides, which converts to about 275 g/m². EN 10346, JIS G3302 and GB/T 2518 use grams per square metre directly, which makes cross-reference straightforward once the unit convention is understood. The metric and imperial figures are not interchangeable at face value; the numerical difference between 90 and 275 is the unit conversion, not a change in coating weight.
Corrosion Behaviour and Service Life
Corrosion life follows coating mass almost linearly. In a moderate urban or rural atmosphere zinc is consumed at roughly 1 to 2 µm per year, and in chloride-bearing coastal air the rate can double. A Z275 hot-dip coating therefore supports 20 to 40 years of exposure before red rust appears on cut edges, while an electro-galvanized coating of 2 to 3 µm per side is normally adequate for indoor service and for parts that are subsequently painted. Hot-dip coatings also protect sheared edges galvanically, because the surrounding zinc sacrifices itself at the cut. Electro-galvanized coatings offer the same mechanism but with far less zinc reserve, so edge protection is short-lived.
Continuous hot-dip lines anneal the strip in-line in a reducing atmosphere before the pot, which avoids the rolled-in oxide and pitting defects that appear in hot-rolled stock and gives a coating that is pore-free and uniform. Electrolytic layers are by nature porous, and every pore is a starting point for undercutting corrosion when moisture reaches the substrate.
Surface Finish, Forming and Joining
Electro-galvanized surfaces are matte, uniform and free of spangle, which is exactly what automotive and appliance panels require before electrophoretic painting. Hot-dip surfaces are bright with a visible crystalline spangle unless the coil is skin-passed or produced with minimized spangle; both are available and are chosen according to whether the sheet will be left bare or painted. For deep drawing, electro-galvanized material tolerates tighter radii because there is no brittle intermetallic layer to crack, while heavy hot-dip coatings can flake at very small bend radii and are usually formed with a generous radius. Resistance welding is easier on electro-galvanized sheet because there is less zinc to disrupt the nugget; hot-dip sheet welds well too, but electrode life shortens as coating weight rises and ventilation becomes important on thicker coatings.
How Buyers Specify and Verify the Product
A complete purchase specification states the coating route, the coating designation, the surface condition, the mechanical quality and the passivation. EN 10346 covers Z100 through Z600 in grades DX51D to DX57D and also ZA and ZF alloy coatings, ASTM A653 covers G40 through G185 plus A and AZ series, JIS G3302 covers SGCC with Z08 through Z50, and GB/T 2518 mirrors the European scheme closely. Electrolytic material follows ASTM A879 or JIS G3313. Verification at the mill is normally a triple-spot coating mass test on specimens taken from both ends of the coil, a coating adhesion bend test, magnetic or coulometric thickness checks and a visual spangle and surface inspection. Coils ship with a mill test certificate to EN 10204 3.1, an inner diameter of 508 mm or 610 mm, weights up to about 25 t, and a surface treatment of oil, chromate passivation or anti-fingerprint film according to the customer drawing requirement.
Frequently Asked Questions
Q: Can hot-dip and electro-galvanized coil be substituted for each other?
A: Only after reviewing exposure and forming sequence. Electro-galvanized material is thinner coated, so it suits indoor parts and painted assemblies, while hot-dip coil is required where the bare surface must survive years of weather or where cut-edge protection matters.
Q: What does a coating designation such as Z275 or G90 mean?
A: Z275 is 275 g/m² of zinc over both surfaces under EN 10346, and G90 is 0.90 oz/ft² over both surfaces under ASTM A653. The two describe essentially the same coating weight in different unit systems.
Q: Which coating is better for exposed roofing and cladding?
A: Hot-dip. Roof and wall panels are expected to last decades outdoors, and the zinc-iron alloy layer plus 20 to 40 µm of coating per side provides the reserve needed for that service, usually followed by a paint or colour coating.
Q: Does galvanizing affect downstream forming or painting?
A: The zinc layer deforms with the steel at normal bend radii. Painted lines normally require a chromate or chromium-free passivation and a light oil film so that the primer keys to the zinc instead of flaking at the bend.
Q: What documents and tests accompany a galvanized coil shipment?
A: A mill test certificate to EN 10204 3.1 reporting chemical composition and mechanical properties, coating mass results from a triple-spot test, and dimensional inspection covering thickness, width, camber and coil weight are the standard package.